Feeder Cable

50Ω Low Loss Corrugated Foam Coaxial Feeder Cable

KANTENNA Type M1110001-V00 M1210001-V00 M2110001-V00 M2210001-V00
Cable Type 1/4" SuperFlex
PE Jacket
1/4" SuperFlex
FRPE Jacket
3/8" SuperFlex
PE Jacket
3/8" SuperFlex
FRPE Jacket
Construction
Inner Conductor CCA Wire CCA Wire CCA Wire CCA Wire
Inner Conductor Size (mm) 1.90 ±0.05 1.90 ±0.05 2.60 ±0.05 2.60 ±0.05
Outer Conductor Helical Corrugated
Copper Tube
Helical Corrugated
Copper Tube
Helical Corrugated
Copper Tube
Helical Corrugated
Copper Tube
Outer Conductor Size (mm) 6.40 ±0.15 6.40 ±0.15 9.00 ±0.15 9.00 ±0.15
Cable Diameter (mm) 7.50 ±0.15 7.50 ±0.15 10.4 ±0.15 10.4 ±0.15
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 13 / 25 13 / 25 15 / 40 15 / 40
Bending Moment (Nm) 1.5 1.5 2.5 2.5
Tensile Strength (N) 600 600 600 600
Flat Plate Crush Strength (N/mm) 8 8 13 13
Storage Temp. (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +60 -25 to +60 -40 to +60 -25 to +60
Operating Temp. (°C) -55 to +85 -30 to +80 -55 to +85 -30 to +80
Cable Weight (kg/km), reference only 65 80 105 115
Electrical Characteristics
Characteristic Impedance (ohm) 50 ±1 50 ±1 50 ±1 50 ±1
Capacitance (pF/m) 83 83 82 82
Velocity (%) 81 81 81 81
Insulation Resistance (MΩ/km) > 5 x 103 > 5 x 103 > 5 x 103 > 5 x 103
DC Breakdown Voltage (V) 2,000 2,000 2,500 2,500
DC Resistance (/km), Inner Conductor 10.2 10.2 5.52 5.52
DC Resistance (/km), Outer Conductor 7.25 7.25 5.25 5.25
Peak Power Rating (kW) 6.4 6.4 12 12
Jacket Spark Voltage (Vrms) 5,000 5,000 3,000 3,000
Shielding Attenuation (dB) >> 120 >> 120 >> 120 >> 120
Cut-off Frequency (GHz) 20.4 20.4 13.4 13.4
VSWR 1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
3rd Order PIM (dBc, @2x43dBm) ≤ -160 ≤ -160 ≤ -160 ≤ -160
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
100 5.95 5.95 4.2 4.2
450 13.15 13.15 9.18 9.18
900 18.56 18.56 13.3 13.3
2000 28.57 28.57 21.21 21.21
2700 33.71 33.71 25.49 25.49
3800 40.96 40.96 31.45 31.45
Typical Average Power
Frequency (MHz) Average Power (kW)
100 1.15 1.15 3.52 3.52
450 0.55 0.55 1.59 1.59
900 0.37 0.37 1.1 1.1
2000 0.23 0.23 0.71 0.71
2700 0.2 0.2 0.6 0.6
3800 0.16 0.16 0.51 0.51

 

 

KANTENNA Type M3110001-V00 M3210001-V00 M3310001-V00 M3410001-V00
Cable Type 1/2" SuperFlex
PE Jacket
1/2" SuperFlex
FRPE Jacket
1/2" Normal
PE Jacket
1/2" Normal
FRPE Jacket
Construction
Inner Conductor CCA Wire CCA Wire CCA Wire CCA Wire
Inner Conductor Size (mm) 3.60 ±0.05 3.60 ±0.05 4.80 ±0.05 4.80 ±0.05
Outer Conductor Helical Corrugated
Copper Tube
Helical Corrugated
Copper Tube
Annular Corrugated
Copper Tube
Annular Corrugated
Copper Tube
Outer Conductor Size (mm) 12.00 ±0.15 12.00 ±0.15 13.80 ±0.15 13.80 ±0.15
Cable Diameter (mm) 13.40 ±0.20 13.40 ±0.20 15.70 ±0.20 15.70 ±0.20
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 25 / 55 25 / 55 50 / 125 50 / 125
Bending Moment (Nm) 3 3 5 5
Tensile Strength (N) 750 750 1050 1050
Flat Plate Crush Strength (N/mm) 15 15 16 16
Storage Temp. (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +60 -25 to +60 -40 to +60 -25 to +60
Operating Temp. (°C) -55 to +85 -30 to +80 -55 to +85 -30 to +80
Cable Weight (kg/km), reference only 140 150 185 200
Electrical Characteristics
Characteristic Impedance (ohm) 50 ±1 50 ±1 50 ±1 50 ±1
Capacitance (pF/m) 83 83 76 76
Velocity (%) 81 81 87 87
Insulation Resistance (MΩ/km) > 1 x 104 > 1 x 104 > 1 x 104 > 1 x 104
DC Breakdown Voltage (V) 2,500 2,500 6,000 6,000
DC Resistance (/km), Inner Conductor  2.97  2.97  1.62  1.62
DC Resistance (/km), Outer Conductor  6.2  6.2  3.5  3.5
Peak Power Rating (kW) 15.6 15.6 40 40
Jacket Spark Voltage (Vrms) 5,000 5,000 8,000 8,000
Shielding Attenuation (dB) >> 120 >> 120 >> 120 >> 120
Cut-off Frequency (GHz) 10.2 10.2 8.8 8.8
VSWR 1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
3rd Order PIM (dBc, @2x43dBm) ≤ -160 ≤ -160 ≤ -160 ≤ -160
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
100 3.31 3.31 2.17 2.17
450 7.59 7.59 4.75 4.75
900 11.21 11.21 6.86 6.86
2000 17.22 17.22 10.72 10.72
2700 20.74 20.74 12.7 12.7
3800 24.83 24.83 15.36 15.36
Typical Average Power
Frequency (MHz) Average Power (kW)
100 3.16 3.16 3.52 3.52
450 1.38 1.38 1.59 1.59
900 0.95 0.95 1.1 1.1
2000 0.6 0.6 0.71 0.71
2700 0.5 0.5 0.6 0.6
3800 0.42 0.42 0.51 0.51

 

 

KANTENNA Type M4310001-V00 M4410001-V00 M5310001-V00 M5410001-V00
Cable Type 7/8" Normal
PE Jacket
7/8" Normal
FRPE Jacket
1-1/4" Normal
PE Jacket
1-1/4" Normal
FRPE Jacket
Construction
Inner Conductor Copper Tube Copper Tube Copper Tube Copper Tube
Inner Conductor Size (mm) 9.00 ±0.10 9.00 ±0.10 13.10 ±0.10 13.10 ±0.10
Outer Conductor Annular Corrugated
Copper Tube
Annular Corrugated
Copper Tube
Annular Corrugated
Copper Tube
Annular Corrugated
Copper Tube
Outer Conductor Size (mm) 24.90 ±0.25 24.90 ±0.25 35.80 ±0.25 35.80 ±0.25
Cable Diameter (mm) 27.50 ±0.25 27.50 ±0.25 38.50 ±0.30 38.50 ±0.30
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 120 / 250 120 / 250 200 / 380 200 / 380
Bending Moment (Nm) 18 18 50 50
Tensile Strength (N) 1,400 1,400 2,500 2,500
Flat Plate Crush Strength (N/mm) 14 14 20 20
Storage Temp. (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +60 -25 to +60 -40 to +60 -25 to +60
Operating Temp. (°C) -55 to +85 -30 to +80 -55 to +85 -30 to +80
Cable Weight (kg/km), reference only 370 420 710 800
Electrical Characteristics
Characteristic Impedance (ohm) 50 ±1 50 ±1 50 ±1 50 ±1
Capacitance (pF/m) 76 76 76 76
Velocity (%) 87 87 88 88
Insulation Resistance (MΩ/km) > 1 x 104 > 1 x 104 > 1 x 104 > 1 x 104
DC Breakdown Voltage (V) 10,000 10,000 10,000 10,000
DC Resistance (/km), Inner Conductor  2.15  2.15  1.26  1.26
DC Resistance (/km), Outer Conductor  2.10  2.10  1.17  1.17
Peak Power Rating (kW) 90 90 310 310
Jacket Spark Voltage (Vrms) 8,000 8,000 10,000 10,000
Shielding Attenuation (dB) >> 120 >> 120 >> 120 >> 120
Cut-off Frequency (GHz) 5.2 5.2 3.7 3.7
VSWR 1.10
(0.8GHz-1GHz)
1.10
(0.8GHz-1GHz)
1.13
(0.8GHz-1GHz)
1.13
(0.8GHz-1GHz)
1.13
(1.7GHz-2.2GHz)
1.13
(1.7GHz-2.2GHz)
1.15
(1.7GHz-2.5GHz)
1.15
(1.7GHz-2.5GHz)
1.15
(2.2GHz-4GHz)
1.15
(2.2GHz-4GHz)
1.20
(2.5GHz-3GHz)
1.20
(2.5GHz-3GHz)
3rd Order PIM (dBc, @2x43dBm) ≤ -160 ≤ -160 ≤ -160 ≤ -160
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
100 1.17 1.17 0.84 0.84
450 2.65 2.65 1.92 1.92
900 3.86 3.86 2.86 2.86
2000 6.12 6.12 4.48 4.48
2700 7.28 7.28 5.36 5.36
3800 8.77 8.77    
Typical Average Power
Frequency (MHz) Average Power (kW)
100 9.17 9.17 12.9 12.9
450 3.73 3.73 5.4 5.4
900 2.34 2.34 3.72 3.72
2000 1.63 1.63 2.33 2.33
2700 1.25 1.25 1.86 1.86
3800 1.01 1.01    

 

 

 

KANTENNA Type M6310001-V00 M6410001-V00
Cable Type 1-5/8" Normal
PE Jacket
1-5/8" Normal
FRPE Jacket
Construction
Inner Conductor Copper Tube Copper Tube
Inner Conductor Size (mm) 17.30 ±0.20 17.30 ±0.20
Outer Conductor Annular Corrugated
Copper Tube
Annular Corrugated
Copper Tube
Outer Conductor Size (mm) 46.50 ±0.30 46.50 ±0.30
Cable Diameter (mm) 49.50 ±0.50 49.50 ±0.50
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 280 / 500 280 / 500
Bending Moment (Nm) 60 60
Tensile Strength (N) 3,000 3,000
Flat Plate Crush Strength (N/mm) 20 20
Storage Temp. (°C) -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +60 -25 to +60
Operating Temp. (°C) -55 to +85 -30 to +80
Cable Weight (kg/km), reference only 1000 1100
Electrical Characteristics
Characteristic Impedance (ohm) 50 ±1 50 ±1
Capacitance (pF/m) 76 76
Velocity (%) 88 88
Insulation Resistance (MΩ/km) > 1 x 104 > 1 x 104
DC Breakdown Voltage (V) 15,000 15,000
DC Resistance (/km), Inner Conductor  1.5  1.5
DC Resistance (/km), Outer Conductor  0.85  0.85
Peak Power Rating (kW) 310 310
Jacket Spark Voltage (Vrms) 10,000 10,000
Shielding Attenuation (dB) >> 120 >> 120
Cut-off Frequency (GHz) 3.7 3.7
VSWR 1.15
(0.8GHz-1GHz)
1.15
(0.8GHz-1GHz)
1.2
(1.7GHz-2.5GHz)
1.2
(1.7GHz-2.5GHz)
3rd Order PIM (dBc, @2x43dBm) ≤ -160 ≤ -160
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
100 0.68 0.68
450 1.57 1.57
900 2.35 2.35
2000 3.82 3.82
2700 4.65 4.65
Typical Average Power
Frequency (MHz) Average Power (kW)
100 18 18
450 7.45 7.45
900 4.97 4.97
2000 3.05 3.05
2700 2.43 2.43

 

 

Remarks:    
1) All values are typical.  Please consult Kantenna Sales Reps for detail specifications and individual datasheets.
2) Customized designs are available upon discussion.
3) Data are subjected to change without prior notice.

 

 

We represent high quality and produce products in the highest calibre.

Contact us now